126 research outputs found

    Ultracapacitors for port crane applications: Sizing and techno-economic analysis

    Get PDF
    The use of energy storage with high power density and fast response time at container terminals (CTs) with a power demand of tens of megawatts is one of the most critical factors for peak reduction and economic benefits. Peak shaving can balance the load demand and facilitate the participation of small power units in generation based on renewable energies. Therefore, in this paper, the economic efficiency of peak demand reduction in ship to shore (STS) cranes based on the ultracapacitor (UC) energy storage sizing has been investigated. The results show the UC energy storage significantly reduce the peak demand, increasing the load factor, load leveling, and most importantly, an outstanding reduction in power and energy cost. In fact, the suggested approach is the start point to improve reliability and reduce peak demand energy consumption

    A nearly zero-energy microgrid testbed laboratory: Centralized control strategy based on SCADA system

    Get PDF
    Currently, despite the use of renewable energy sources (RESs), distribution networks are facing problems, such as complexity and low productivity. Emerging microgrids (MGs) with RESs based on supervisory control and data acquisition (SCADA) are an effective solution to control, manage, and finally deal with these challenges. The development and success of MGs is highly dependent on the use of power electronic interfaces. The use of these interfaces is directly related to the progress of SCADA systems and communication infrastructures. The use of SCADA systems for the control and operation of MGs and active distribution networks promotes productivity and efficiency. This paper presents a real MG case study called the LAMBDA MG testbed laboratory, which has been implemented in the electrical department of the Sapienza University of Rome with a centralized energy management system (CEMS). The real-time results of the SCADA system show that a CEMS can create proper energy balance in a LAMBDA MG testbed and, consequently, minimize the exchange power of the LAMBDA MG and main grid

    Hydrogen vs. Battery in the long-term operation. A comparative between energy management strategies for hybrid renewable microgrids

    Get PDF
    The growth of the world’s energy demand over recent decades in relation to energy intensity and demography is clear. At the same time, the use of renewable energy sources is pursued to address decarbonization targets, but the stochasticity of renewable energy systems produces an increasing need for management systems to supply such energy volume while guaranteeing, at the same time, the security and reliability of the microgrids. Locally distributed energy storage systems (ESS) may provide the capacity to temporarily decouple production and demand. In this sense, the most implemented ESS in local energy districts are small–medium-scale electrochemical batteries. However, hydrogen systems are viable for storing larger energy quantities thanks to its intrinsic high mass-energy density. To match generation, demand and storage, energy management systems (EMSs) become crucial. This paper compares two strategies for an energy management system based on hydrogen-priority vs. battery-priority for the operation of a hybrid renewable microgrid. The overall performance of the two mentioned strategies is compared in the long-term operation via a set of evaluation parameters defined by the unmet load, storage efficiency, operating hours and cumulative energy. The results show that the hydrogen-priority strategy allows the microgrid to be led towards island operation because it saves a higher amount of energy, while the battery-priority strategy reduces the energy efficiency in the storage round trip. The main contribution of this work lies in the demonstration that conventional EMS for microgrids’ operation based on battery-priority strategy should turn into hydrogen-priority to keep the reliability and independence of the microgrid in the long-term operation

    Strategies for improving the sustainability of data centers via energy mix, energy conservation, and circular energy

    Get PDF
    Information and communication technologies (ICT) are increasingly permeating our daily life and we ever more commit our data to the cloud. Events like the COVID-19 pandemic put an exceptional burden upon ICT. This involves increasing implementation and use of data centers, which increased energy use and environmental impact. The scope of this work is to summarize the present situation on data centers as to environmental impact and opportunities for improvement. First, we introduce the topic, presenting estimated energy use and emissions. Then, we review proposed strategies for energy efficiency and conservation in data centers. Energy uses pertain to power distribution, ICT, and non-ICT equipment (e.g., cooling). Existing and prospected strategies and initiatives in these sectors are identified. Among key elements are innovative cooling techniques, natural resources, automation, low-power electronics, and equipment with extended thermal limits. Research perspectives are identified and estimates of improvement opportunities are mentioned. Finally, we present an overview on existing metrics, regulatory framework, and bodies concerned

    Microgrid working conditions identification based on cluster analysis. A case study from lambda microgrid

    Get PDF
    This article presents the application of cluster analysis (CA) to data proceeding from a testbed microgrid located at Sapienza University of Rome. The microgrid consists of photovoltaic (PV), battery storage system (BESS), emergency generator set, and different types of load with a real-time energy management system based on supervisory control and data acquisition. The investigation is based on the area-related approach - the CA algorithm considers the input database consisting of data from all measurement points simultaneously. Under the investigation, different distance measures (Euclidean, Chebyshev, or Manhattan), as well as an approach to the optimal number of cluster selections. Based on the investigation, the four different clusters that represent working conditions were obtained using methods to define an optimal number of clusters. Cluster 1 represented time with high PV production; cluster 2 represented time with relatively low PV production and when BESS was charged; cluster 3 represents time with relatively high PV production and when BESS was charged; cluster 4 represents time without PV production. Additionally, after the clustering process, a deep analysis was performed in relation to the working condition of the microgrid

    Intelligent energy management based on SCADA system in a real Microgrid for smart building applications

    Get PDF
    Energy management is one of the main challenges in Microgrids (MGs) applied to Smart Buildings (SBs). Hence, more studies are indispensable to consider both modeling and operating aspects to utilize the upcoming results of the system for the different applications. This paper presents a novel energy management architecture model based on complete Supervisory Control and Data Acquisition (SCADA) system duties in an educational building with an MG Laboratory (Lab) testbed, which is named LAMBDA at the Electrical and Energy Engineering Department of the Sapienza University of Rome. The LAMBDA MG Lab simulates in a small scale a SB and is connected with the DIAEE electrical network. LAMBDA MG is composed of a Photovoltaic generator (PV), a Battery Energy Storage System (BESS), a smart switchboard (SW), and different classified loads (critical, essential, and normal) some of which are manageable and controllable (lighting, air conditioning, smart plugs operating into the LAB). The aim of the LAMBDA implementation is making the DIAEE smart for energy saving purposes. In the LAMBDA Lab, the communication architecture consists in a complex of master/slave units and actuators carried out by two main international standards, Modbus (industrial serial standard for electrical and technical monitoring systems) and Konnex (an open standard for commercial and domestic building automation). Making the electrical department smart causes to reduce the required power from the main grid. Hence, to achieve the aims, results have been investigated in two modes. Initially, the real-time mode based on the SCADA system, which reveals real daily power consumption and production of different sources and loads. Next, the simulation part is assigned to shows the behavior of the main grid, loads and BESS charging and discharging based on energy management system. Finally, the proposed model has been examined in different scenarios and evaluated from the economic aspect

    Joint Model Predictive Control of Electric and Heating Resources in a Smart Building

    Get PDF
    The new challenge in power systems design and operation is to organize and control smart micro grids supplying aggregation of users and special loads as electric vehicles charging stations. The presence of renewable and storage can help the optimal operation only if a good control manages all the elements of the grid. New models of green buildings and energy communities are proposed. For a real application they need an appropriate and advanced power system equipped with a building automation control system. This article presents an economic model predictive control approach to the problem of managing the electric and heating resources in a smart building in a coordinated way, for the purpose of achieving in real time nearly zero energy consumption and automated participation to demand response programs. The proposed control, leveraging a mixed integer quadratic programming problem, allows to meet manifold thermal and electric users' requirements and react to inbound demand response signals, while still guaranteeing stable operation of the building's electric and thermal storage equipment. The simulation results, performed for a real case study in Italy, highlight the peculiarities of the proposed approach in the joint handling of electric and thermal building flexibility

    Combined DC-Link Fed Parallel-VSI-Based DSTATCOM for Power Quality Improvement of a Solar DG Integrated System

    Get PDF
    In present day power systems, Power Quality (PQ) issues are causing great concern owing to the increased use of power electronic controlled drives and fluctuating and other non-linear loads. This problem is further aggravated by a steady increase in the integration of renewable energy-based Distribution Generation (DG), employing power electronic converters to distribution systems. Custom power devices with suitable control strategies provide an effective solution to these power quality issues. In this work, a typical three-phase distribution system supplying non-linear load and with DG integration is considered. A shunt connected DSTATCOM at PCC of the system is employed to mitigate power quality concerns. Initially, a parallel-VSI based DSTATCOM configuration, employing individual DC-Link and working basically on the principle of current sharing, has been proposed. The analysis is carried out for variable load conditions for PQ enhancement making use of a more effective control theory viz. Instantaneous Real-Reactive Power (IRP) theory for the generation of suitable switching patterns to the individual VSIs of the parallel DSTATCOM. Further, an improvement over the above configuration viz. combined/common DC-Link-fed parallel DSTATCOM is proposed. This configuration has the advantages of minimized sensing elements, reliable operation and low-cost compensation. A similar analysis is carried out for PQ improvement, making use of the same IRP theory with some modifications (known as MIRP theory). The effectiveness of this configuration is established from the simulation results. In all the above cases, the analyses are carried out using MATLAB/Simulink platform and the simulation results are presented in detail. Thus, the proposed parallel VSIs-based DSTATCOM configurations employing suitable control strategies provide effective solutions for power quality issues under varying load conditions in conventional distribution systems

    Influence of LV Neutral Grounding on Global Earthing Systems

    Get PDF
    International Standards define a Global Earthing System as an earthing net created interconnecting local Earthing Systems (generally through the shield of MV cables and/or bare buried conductors). In Italy the Regulatory Authority for Electricity and Gas requires Distributors to guarantee the electrical continuity of LV neutral conductor. This requirement has led to the standard practice of realizing “reinforcement groundings” along the LV neutral conductor path and at users’ delivery cabinet. Moreover, in urban high load scenarios (prime candidates to be part of a Global Earthing System), it is common that LV distribution scheme creates, trough neutral conductors, an effective connection between grounding systems of MV/LV substations, modifying Global Earthing System consistency. Aim of this paper is to evaluate the effect, in terms of electrical safety, of the above mentioned LV neutral distribution scheme when an MV-side fault to ground occurs. At this purpose simulations are carried out on a realistic urban test case and suitable evaluation indexes are proposed

    A Practical Method to Test the Safety of HV/MV Substation Grounding System

    Get PDF
    The adequacy of a Grounding System (GS) to the safety conditions has to be periodically tested by measurements. The test methods and techniques used to verify the electrical characteristics of the GS include the measurements of step and touch voltages. The goal of the test is to verify that touch voltage and step voltage remain below a safe value in all the zones of the installation. The measurements can present some operational difficulties. The purpose of this paper is to present the procedure, step-by-step, of a practical method of measuring touch/step voltages in grounding systems located in urban or industrial areas with reduced accessibility. The suggested method uses auxiliary current electrodes located at short distances. This paper demonstrates by test measurements done in a real case that the method provides conservative results
    • …